{"id":3884,"date":"2020-03-11T13:46:00","date_gmt":"2020-03-11T12:46:00","guid":{"rendered":"https:\/\/safetyandsis.com\/fallos-sistematicos\/"},"modified":"2025-08-18T20:39:08","modified_gmt":"2025-08-18T19:39:08","slug":"fallos-sistematicos","status":"publish","type":"post","link":"https:\/\/safetyandsis.com\/es\/fallos-sistematicos\/","title":{"rendered":"Fallos Sistem\u00e1ticos"},"content":{"rendered":"\r\n<h2 class=\"wp-block-heading\">Fallos Sistem\u00e1ticos<\/h2>\r\n\r\n\r\n\r\n<p style=\"text-align: justify;\">La <a href=\"https:\/\/safetyandsis.com\/es\/como-cumplir-la-iec-61511\/\">IEC 61511<\/a> define los fallos sistem\u00e1ticos como aquellos <em>fallos \u201cpre-existentes\u201d que s\u00f3lo <strong>pueden ser eliminados<\/strong> modificando el dise\u00f1o, el proceso de fabricaci\u00f3n, los procedimientos de operaci\u00f3n y mantenimiento, la documentaci\u00f3n u otros factores.<\/em><\/p>\r\n\r\n\r\n\r\n<p style=\"text-align: justify;\">La particularidad de los fallos sistem\u00e1ticos es que est\u00e1n \u201c<strong>ocultos<\/strong>\u201d y pueden no manifestarse nunca ni ser detectados, adem\u00e1s son dif\u00edciles de medir. Casi siempre son fallos directamente relacionados con errores humanos.<\/p>\r\n\r\n\r\n\r\n<h3><strong>Ejemplos de fallos sistem\u00e1ticos:<\/strong><\/h3>\r\n\r\n\r\n\r\n<p style=\"text-align: justify;\">-Error en una <strong>Hoja de Datos<\/strong> de un instrumento (fallo humano en la especificaci\u00f3n). Fallo durante la fase de An\u00e1lisis del <a href=\"https:\/\/safetyandsis.com\/es\/ciclo-de-vida-del-sis\/\">ciclo de vida del SIS.<\/a><\/p>\r\n\r\n\r\n\r\n<p style=\"text-align: justify;\">&#8211;<strong>Olvidarse un bypass<\/strong> despu\u00e9s de las pruebas (fallo humano o fallo del procedimiento de mantenimiento del SIS). Fallo durante la fase de O &amp; M del ciclo de vida.<\/p>\r\n\r\n\r\n\r\n<p style=\"text-align: justify;\">&#8211;<strong>Error de calibraci\u00f3n<\/strong> de un instrumento por exceso de fatiga del operario o por estr\u00e9s (fallo humano relacionado con la organizaci\u00f3n, la formaci\u00f3n y\/o los recursos disponibles en la Planta). Fallo durante la fase de O &amp; M del ciclo de vida.<\/p>\r\n\r\n\r\n\r\n<p style=\"text-align: justify;\">-Fallo en el <strong>software de aplicaci\u00f3n <\/strong>del Logic Solver, normalmente conocido como \u201c<strong>bug<\/strong>\u201d (fallo humano debido a m\u00faltiples factores: programador sin experiencia, pruebas FAT\/SAT poco rigurosas, error en el Diagrama L\u00f3gico o en la matriz Causa-Efecto, etc.). Fallo durante la fase de Dise\u00f1o e Implementaci\u00f3n del ciclo de vida del SIS.<\/p>\r\n\r\n\r\n\r\n<p style=\"text-align: justify;\">Existe una gran diferencia entre los \u201cfallos de hardware\u201d y los \u201cfallos sistem\u00e1ticos\u201d. Los primeros (random hardware failures) son cuantificables y son los que utilizamos cuando calculamos el valor de la Probabilidad de Fallo (PFDavg \/ PFH). Sin embargo, <strong>muchos fallos sistem\u00e1ticos tienen un 100% de probabilidad de ocurrir<\/strong>, como puede ser el caso de un error de calibraci\u00f3n, un error en la especificaci\u00f3n, un error de software, etc. Por tanto, este tipo de fallos sistem\u00e1ticos <strong>pueden ser potencialmente detectados y eliminados <\/strong>si logramos reproducirlos con las pruebas adecuadas.<\/p>\r\n\r\n\r\n\r\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" class=\"lazyload alignnone wp-image-4047 size-full\" src=\"https:\/\/safetyandsis.com\/\/wp-content\/uploads\/fallos-del-SIS-es.webp\" data-orig-src=\"https:\/\/safetyandsis.com\/\/wp-content\/uploads\/fallos-del-SIS-es.webp\" alt=\"Fallos Sistem\u00e1ticos\" width=\"785\" height=\"405\" srcset=\"data:image\/svg+xml,%3Csvg%20xmlns%3D%27http%3A%2F%2Fwww.w3.org%2F2000%2Fsvg%27%20width%3D%27785%27%20height%3D%27405%27%20viewBox%3D%270%200%20785%20405%27%3E%3Crect%20width%3D%27785%27%20height%3D%27405%27%20fill-opacity%3D%220%22%2F%3E%3C%2Fsvg%3E\" data-srcset=\"https:\/\/safetyandsis.com\/\/wp-content\/uploads\/fallos-del-SIS-es-200x103.webp 200w, https:\/\/safetyandsis.com\/\/wp-content\/uploads\/fallos-del-SIS-es-300x155.webp 300w, https:\/\/safetyandsis.com\/\/wp-content\/uploads\/fallos-del-SIS-es-400x206.webp 400w, https:\/\/safetyandsis.com\/\/wp-content\/uploads\/fallos-del-SIS-es-600x310.webp 600w, https:\/\/safetyandsis.com\/\/wp-content\/uploads\/fallos-del-SIS-es-768x396.webp 768w, https:\/\/safetyandsis.com\/\/wp-content\/uploads\/fallos-del-SIS-es.webp 785w\" data-sizes=\"auto\" data-orig-sizes=\"(max-width: 785px) 100vw, 785px\" \/><\/figure>\r\n\r\n\r\n\r\n<h3 class=\"wp-block-heading\">\u00bfCu\u00e1l es la forma de minimizar los fallos sistem\u00e1ticos?<\/h3>\r\n\r\n\r\n\r\n<p style=\"text-align: justify;\"><strong>La Gesti\u00f3n de la Seguridad Funcional <\/strong>ayuda a prevenir la introducci\u00f3n de fallos sistem\u00e1ticos. Hay que definir correctamente todas las actividades del <a href=\"https:\/\/safetyandsis.com\/es\/ciclo-de-vida-del-sis\/\">Ciclo de Vida del SIS<\/a>, asignar responsables y asegurarnos que las personas son competentes para ello. Esto est\u00e1 contemplado en la secci\u00f3n 5 de la IEC 61511.<\/p>\r\n\r\n\r\n\r\n<p>Algunas recomendaciones:<\/p>\r\n\r\n\r\n\r\n<ul>\r\n<li>El uso de <strong>productos certificados<\/strong> para el dise\u00f1o SIS (la \u00abCapacidad Sistem\u00e1tica\u00bb del sensor, PLC, actuador, etc. es un requisito que ayuda a minimizar los fallos sistem\u00e1ticos del fabricante).<\/li>\r\n<li>Aseg\u00farese de que el <strong>personal<\/strong> relacionado con el SIS <strong>est\u00e9 capacitado y sea competente.<\/strong><\/li>\r\n<li>Realizar <strong>evaluaciones peri\u00f3dicas del personal del SIS.<\/strong><\/li>\r\n<li>Aseg\u00farese de que los <strong>procedimientos sean completos, claros<\/strong> y que se <strong>sigan.<\/strong><\/li>\r\n<li>Utilice <strong>listas de verificaci\u00f3n<\/strong> para asegurarse de que no falte nada.<\/li>\r\n<li>Mantenga <strong>un buen registro de los documentos y actividades del SIS<\/strong> (especificaciones, verificaci\u00f3n y validaci\u00f3n, formaci\u00f3n, registro de fallos, etc.).<\/li>\r\n<li>Aseg\u00farese de que existe un <strong>plan de gesti\u00f3n de la seguridad funcional<\/strong> y de que se sigue.<\/li>\r\n<li>Realice <strong>evaluaciones<\/strong> (evaluaciones de seguridad funcional) y <strong>auditor\u00edas del SIS.<\/strong><\/li>\r\n<li>Realice <strong>el seguimiento y la reparaci\u00f3n de cualquier no conformidad<\/strong> en un plazo razonable.<\/li>\r\n<li><strong>Aplique las posibles recomendaciones<\/strong> de las evaluaciones de seguridad funcional y las auditor\u00edas.<\/li>\r\n<\/ul>\r\n\r\n\r\n\r\n<h3 class=\"wp-block-heading\">Conclusi\u00f3n<\/h3>\r\n\r\n\r\n\r\n<p style=\"text-align: justify;\"><strong>La integridad de las <a href=\"https:\/\/safetyandsis.com\/es\/que-es-una-funcion-instrumentada-de-seguridad-iec61511\/\">Funciones Instrumentadas de Seguridad <\/a><\/strong>(SIF) y del SIS en su conjunto <strong>no depende exclusivamente de los Fallos Hardware<\/strong>, es decir, del cumplimiento de la Probabilidad de Fallo (PFDavg), de la Capacidad Sistem\u00e1tica y de las llamadas \u201cRestricciones de Arquitectura\u201d. Esto es s\u00f3lo una parte.<\/p>\r\n\r\n\r\n\r\n<p style=\"text-align: justify;\"><strong>Los fallos sistem\u00e1ticos son los responsables de la mayor\u00eda de los accidentes <\/strong>en la industria de proceso y debe ser siempre el <strong>foco<\/strong> de los responsables de la Seguridad Funcional de la Planta.<\/p>\r\n\r\n\r\n\r\n<p style=\"text-align: justify;\">Podemos realizar muchos esfuerzos en conseguir una Funci\u00f3n de Seguridad SIL-3, pero <strong>para mantener este SIL a lo largo del tiempo necesitamos realizar una buena Gesti\u00f3n de la Seguridad Funcional.<\/strong><\/p>\r\n<p>Una SIF SIL-2 o SIL-3 con productos certificados pero con un mantenimiento poco eficiente no es ni \u00edntegra ni segura.<\/p>\r\n<p>Enlace relacionado:<\/p>\r\n<p><a href=\"https:\/\/www.exida.com\/Resources\/Term\/systematic_failure\" target=\"_blank\" rel=\"noreferrer noopener\" aria-label=\"Systematic Failures by Exida (opens in a new tab)\">Systematic Failures by Exida<\/a><\/p>\r\n","protected":false},"excerpt":{"rendered":"<p>Fallos Sistem\u00e1ticos La IEC 61511 define los fallos sistem\u00e1ticos como aquellos fallos \u201cpre-existentes\u201d que s\u00f3lo pueden ser eliminados modificando el dise\u00f1o, el proceso de fabricaci\u00f3n, los procedimientos de operaci\u00f3n y mantenimiento, la documentaci\u00f3n u otros factores. La particularidad de los fallos sistem\u00e1ticos es que est\u00e1n \u201cocultos\u201d y pueden no manifestarse<\/p>\n","protected":false},"author":3,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[165,185,161,186],"tags":[],"class_list":["post-3884","post","type-post","status-publish","format-standard","hentry","category-ciclo-de-vida-es","category-iec-61511-es-2","category-lo-basico","category-sif-es-2"],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.9 (Yoast SEO v27.9) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Fallos Sistem\u00e1ticos del SIS &#8212; Seguridad Funcional<\/title>\n<meta name=\"description\" content=\"Los fallos sistem\u00e1ticos est\u00e1n muy relacionados con los fallos humanos y deben ser el foco de cualquier responsable de la Seguridad Funcional de la Planta.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/safetyandsis.com\/es\/fallos-sistematicos\/\" \/>\n<meta property=\"og:locale\" content=\"es_ES\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Fallos Sistem\u00e1ticos\" \/>\n<meta property=\"og:description\" content=\"Los fallos sistem\u00e1ticos est\u00e1n muy relacionados con los fallos humanos y deben ser el foco de cualquier responsable de la Seguridad Funcional de la Planta.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/safetyandsis.com\/es\/fallos-sistematicos\/\" \/>\n<meta property=\"og:site_name\" content=\"Seguridad Funcional\" \/>\n<meta property=\"article:published_time\" content=\"2020-03-11T12:46:00+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-08-18T19:39:08+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/safetyandsis.com\/\/wp-content\/uploads\/fallos-del-SIS-es.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"785\" \/>\n\t<meta property=\"og:image:height\" content=\"405\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"author\" content=\"Enertria\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/safetyandsis.com\\\/es\\\/fallos-sistematicos\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/safetyandsis.com\\\/es\\\/fallos-sistematicos\\\/\"},\"author\":{\"name\":\"Enertria\",\"@id\":\"https:\\\/\\\/safetyandsis.com\\\/#\\\/schema\\\/person\\\/8cbe0b108f350d161805c143258aa7ee\"},\"headline\":\"Fallos Sistem\u00e1ticos\",\"datePublished\":\"2020-03-11T12:46:00+00:00\",\"dateModified\":\"2025-08-18T19:39:08+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/safetyandsis.com\\\/es\\\/fallos-sistematicos\\\/\"},\"wordCount\":711,\"publisher\":{\"@id\":\"https:\\\/\\\/safetyandsis.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/safetyandsis.com\\\/es\\\/fallos-sistematicos\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/safetyandsis.com\\\/\\\/wp-content\\\/uploads\\\/fallos-del-SIS-es.webp\",\"articleSection\":[\"Ciclo de vida\",\"IEC 61511\",\"Lo b\u00e1sico\",\"SIF\"],\"inLanguage\":\"es\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/safetyandsis.com\\\/es\\\/fallos-sistematicos\\\/\",\"url\":\"https:\\\/\\\/safetyandsis.com\\\/es\\\/fallos-sistematicos\\\/\",\"name\":\"Fallos Sistem\u00e1ticos del SIS &#8212; Seguridad Funcional\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/safetyandsis.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/safetyandsis.com\\\/es\\\/fallos-sistematicos\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/safetyandsis.com\\\/es\\\/fallos-sistematicos\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/safetyandsis.com\\\/\\\/wp-content\\\/uploads\\\/fallos-del-SIS-es.webp\",\"datePublished\":\"2020-03-11T12:46:00+00:00\",\"dateModified\":\"2025-08-18T19:39:08+00:00\",\"description\":\"Los fallos sistem\u00e1ticos est\u00e1n muy relacionados con los fallos humanos y deben ser el foco de cualquier responsable de la Seguridad Funcional de la Planta.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/safetyandsis.com\\\/es\\\/fallos-sistematicos\\\/#breadcrumb\"},\"inLanguage\":\"es\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/safetyandsis.com\\\/es\\\/fallos-sistematicos\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"es\",\"@id\":\"https:\\\/\\\/safetyandsis.com\\\/es\\\/fallos-sistematicos\\\/#primaryimage\",\"url\":\"https:\\\/\\\/safetyandsis.com\\\/\\\/wp-content\\\/uploads\\\/fallos-del-SIS-es.webp\",\"contentUrl\":\"https:\\\/\\\/safetyandsis.com\\\/\\\/wp-content\\\/uploads\\\/fallos-del-SIS-es.webp\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/safetyandsis.com\\\/es\\\/fallos-sistematicos\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/safetyandsis.com\\\/es\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Fallos Sistem\u00e1ticos\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/safetyandsis.com\\\/#website\",\"url\":\"https:\\\/\\\/safetyandsis.com\\\/\",\"name\":\"Functional Safety\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/safetyandsis.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/safetyandsis.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"es\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/safetyandsis.com\\\/#organization\",\"name\":\"Enertria\",\"url\":\"https:\\\/\\\/safetyandsis.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"es\",\"@id\":\"https:\\\/\\\/safetyandsis.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/safetyandsis.com\\\/\\\/wp-content\\\/uploads\\\/logo-safetyandsis-h-f.webp\",\"contentUrl\":\"https:\\\/\\\/safetyandsis.com\\\/\\\/wp-content\\\/uploads\\\/logo-safetyandsis-h-f.webp\",\"width\":225,\"height\":160,\"caption\":\"Enertria\"},\"image\":{\"@id\":\"https:\\\/\\\/safetyandsis.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/safetyandsis.com\\\/#\\\/schema\\\/person\\\/8cbe0b108f350d161805c143258aa7ee\",\"name\":\"Enertria\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Fallos Sistem\u00e1ticos del SIS &#8212; Seguridad Funcional","description":"Los fallos sistem\u00e1ticos est\u00e1n muy relacionados con los fallos humanos y deben ser el foco de cualquier responsable de la Seguridad Funcional de la Planta.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/safetyandsis.com\/es\/fallos-sistematicos\/","og_locale":"es_ES","og_type":"article","og_title":"Fallos Sistem\u00e1ticos","og_description":"Los fallos sistem\u00e1ticos est\u00e1n muy relacionados con los fallos humanos y deben ser el foco de cualquier responsable de la Seguridad Funcional de la Planta.","og_url":"https:\/\/safetyandsis.com\/es\/fallos-sistematicos\/","og_site_name":"Seguridad Funcional","article_published_time":"2020-03-11T12:46:00+00:00","article_modified_time":"2025-08-18T19:39:08+00:00","og_image":[{"width":785,"height":405,"url":"https:\/\/safetyandsis.com\/\/wp-content\/uploads\/fallos-del-SIS-es.webp","type":"image\/webp"}],"author":"Enertria","twitter_card":"summary_large_image","schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/safetyandsis.com\/es\/fallos-sistematicos\/#article","isPartOf":{"@id":"https:\/\/safetyandsis.com\/es\/fallos-sistematicos\/"},"author":{"name":"Enertria","@id":"https:\/\/safetyandsis.com\/#\/schema\/person\/8cbe0b108f350d161805c143258aa7ee"},"headline":"Fallos Sistem\u00e1ticos","datePublished":"2020-03-11T12:46:00+00:00","dateModified":"2025-08-18T19:39:08+00:00","mainEntityOfPage":{"@id":"https:\/\/safetyandsis.com\/es\/fallos-sistematicos\/"},"wordCount":711,"publisher":{"@id":"https:\/\/safetyandsis.com\/#organization"},"image":{"@id":"https:\/\/safetyandsis.com\/es\/fallos-sistematicos\/#primaryimage"},"thumbnailUrl":"https:\/\/safetyandsis.com\/\/wp-content\/uploads\/fallos-del-SIS-es.webp","articleSection":["Ciclo de vida","IEC 61511","Lo b\u00e1sico","SIF"],"inLanguage":"es"},{"@type":"WebPage","@id":"https:\/\/safetyandsis.com\/es\/fallos-sistematicos\/","url":"https:\/\/safetyandsis.com\/es\/fallos-sistematicos\/","name":"Fallos Sistem\u00e1ticos del SIS &#8212; Seguridad Funcional","isPartOf":{"@id":"https:\/\/safetyandsis.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/safetyandsis.com\/es\/fallos-sistematicos\/#primaryimage"},"image":{"@id":"https:\/\/safetyandsis.com\/es\/fallos-sistematicos\/#primaryimage"},"thumbnailUrl":"https:\/\/safetyandsis.com\/\/wp-content\/uploads\/fallos-del-SIS-es.webp","datePublished":"2020-03-11T12:46:00+00:00","dateModified":"2025-08-18T19:39:08+00:00","description":"Los fallos sistem\u00e1ticos est\u00e1n muy relacionados con los fallos humanos y deben ser el foco de cualquier responsable de la Seguridad Funcional de la Planta.","breadcrumb":{"@id":"https:\/\/safetyandsis.com\/es\/fallos-sistematicos\/#breadcrumb"},"inLanguage":"es","potentialAction":[{"@type":"ReadAction","target":["https:\/\/safetyandsis.com\/es\/fallos-sistematicos\/"]}]},{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/safetyandsis.com\/es\/fallos-sistematicos\/#primaryimage","url":"https:\/\/safetyandsis.com\/\/wp-content\/uploads\/fallos-del-SIS-es.webp","contentUrl":"https:\/\/safetyandsis.com\/\/wp-content\/uploads\/fallos-del-SIS-es.webp"},{"@type":"BreadcrumbList","@id":"https:\/\/safetyandsis.com\/es\/fallos-sistematicos\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/safetyandsis.com\/es\/"},{"@type":"ListItem","position":2,"name":"Fallos Sistem\u00e1ticos"}]},{"@type":"WebSite","@id":"https:\/\/safetyandsis.com\/#website","url":"https:\/\/safetyandsis.com\/","name":"Functional Safety","description":"","publisher":{"@id":"https:\/\/safetyandsis.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/safetyandsis.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"es"},{"@type":"Organization","@id":"https:\/\/safetyandsis.com\/#organization","name":"Enertria","url":"https:\/\/safetyandsis.com\/","logo":{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/safetyandsis.com\/#\/schema\/logo\/image\/","url":"https:\/\/safetyandsis.com\/\/wp-content\/uploads\/logo-safetyandsis-h-f.webp","contentUrl":"https:\/\/safetyandsis.com\/\/wp-content\/uploads\/logo-safetyandsis-h-f.webp","width":225,"height":160,"caption":"Enertria"},"image":{"@id":"https:\/\/safetyandsis.com\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/safetyandsis.com\/#\/schema\/person\/8cbe0b108f350d161805c143258aa7ee","name":"Enertria"}]}},"_links":{"self":[{"href":"https:\/\/safetyandsis.com\/es\/wp-json\/wp\/v2\/posts\/3884","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/safetyandsis.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/safetyandsis.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/safetyandsis.com\/es\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/safetyandsis.com\/es\/wp-json\/wp\/v2\/comments?post=3884"}],"version-history":[{"count":7,"href":"https:\/\/safetyandsis.com\/es\/wp-json\/wp\/v2\/posts\/3884\/revisions"}],"predecessor-version":[{"id":4407,"href":"https:\/\/safetyandsis.com\/es\/wp-json\/wp\/v2\/posts\/3884\/revisions\/4407"}],"wp:attachment":[{"href":"https:\/\/safetyandsis.com\/es\/wp-json\/wp\/v2\/media?parent=3884"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/safetyandsis.com\/es\/wp-json\/wp\/v2\/categories?post=3884"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/safetyandsis.com\/es\/wp-json\/wp\/v2\/tags?post=3884"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}